The automated diagnosis of strabismus using an infrared camera

Min Won Seo, Hee Kyung Yang, Jeong-Min Hwang, Jong Mo Seo

Research output: Chapter in Book/Report/Conference proceedingConference contributionResearchpeer-review

3 Citations (Scopus)

Abstract

This paper is to discuss about how to implement the automatic strabismus examination system. By using the shutter glasses that can control the cover state electrically, cover-uncover test and alternate-cover test are performed according to the flowchart. Test is started by capturing the infrared video images acquired by camcorder. And we can measure the deviation of the eye from the difference of the pupil center and the corneal reflex point. By following the flowchart, type of strabismus could be determined. Developed device showed good results comparable to conventional coveruncover test and alternate cover test.

Original languageEnglish
Title of host publication6th European Conference of the International Federation for Medical and Biological Engineering - MBEC 2014
EditorsIgor Lackovic, Darko Vasic
PublisherSpringer Verlag
Pages142-145
Number of pages4
Volume45
ISBN (Electronic)9783319111278
DOIs
StatePublished - 1 Jan 2015
Event6th European Conference of the International Federation for Medical and Biological Engineering, MBEC 2014 - Dubrovnik, Croatia
Duration: 7 Sep 201411 Sep 2014

Other

Other6th European Conference of the International Federation for Medical and Biological Engineering, MBEC 2014
CountryCroatia
CityDubrovnik
Period7/09/1411/09/14

Fingerprint

Cameras
Infrared radiation
Glass

Keywords

  • Alternate-cover test
  • Cover-uncover test
  • Infrared image
  • Shutter glasses
  • Strabismus

Cite this

Seo, M. W., Yang, H. K., Hwang, J-M., & Seo, J. M. (2015). The automated diagnosis of strabismus using an infrared camera. In I. Lackovic, & D. Vasic (Eds.), 6th European Conference of the International Federation for Medical and Biological Engineering - MBEC 2014 (Vol. 45, pp. 142-145). Springer Verlag. https://doi.org/10.1007/978-3-319-11128-5_36
Seo, Min Won ; Yang, Hee Kyung ; Hwang, Jeong-Min ; Seo, Jong Mo. / The automated diagnosis of strabismus using an infrared camera. 6th European Conference of the International Federation for Medical and Biological Engineering - MBEC 2014. editor / Igor Lackovic ; Darko Vasic. Vol. 45 Springer Verlag, 2015. pp. 142-145
@inproceedings{08a09d4128a0446fa285a717a5924828,
title = "The automated diagnosis of strabismus using an infrared camera",
abstract = "This paper is to discuss about how to implement the automatic strabismus examination system. By using the shutter glasses that can control the cover state electrically, cover-uncover test and alternate-cover test are performed according to the flowchart. Test is started by capturing the infrared video images acquired by camcorder. And we can measure the deviation of the eye from the difference of the pupil center and the corneal reflex point. By following the flowchart, type of strabismus could be determined. Developed device showed good results comparable to conventional coveruncover test and alternate cover test.",
keywords = "Alternate-cover test, Cover-uncover test, Infrared image, Shutter glasses, Strabismus",
author = "Seo, {Min Won} and Yang, {Hee Kyung} and Jeong-Min Hwang and Seo, {Jong Mo}",
year = "2015",
month = "1",
day = "1",
doi = "10.1007/978-3-319-11128-5_36",
language = "English",
volume = "45",
pages = "142--145",
editor = "Igor Lackovic and Darko Vasic",
booktitle = "6th European Conference of the International Federation for Medical and Biological Engineering - MBEC 2014",
publisher = "Springer Verlag",

}

Seo, MW, Yang, HK, Hwang, J-M & Seo, JM 2015, The automated diagnosis of strabismus using an infrared camera. in I Lackovic & D Vasic (eds), 6th European Conference of the International Federation for Medical and Biological Engineering - MBEC 2014. vol. 45, Springer Verlag, pp. 142-145, 6th European Conference of the International Federation for Medical and Biological Engineering, MBEC 2014, Dubrovnik, Croatia, 7/09/14. https://doi.org/10.1007/978-3-319-11128-5_36

The automated diagnosis of strabismus using an infrared camera. / Seo, Min Won; Yang, Hee Kyung; Hwang, Jeong-Min; Seo, Jong Mo.

6th European Conference of the International Federation for Medical and Biological Engineering - MBEC 2014. ed. / Igor Lackovic; Darko Vasic. Vol. 45 Springer Verlag, 2015. p. 142-145.

Research output: Chapter in Book/Report/Conference proceedingConference contributionResearchpeer-review

TY - GEN

T1 - The automated diagnosis of strabismus using an infrared camera

AU - Seo, Min Won

AU - Yang, Hee Kyung

AU - Hwang, Jeong-Min

AU - Seo, Jong Mo

PY - 2015/1/1

Y1 - 2015/1/1

N2 - This paper is to discuss about how to implement the automatic strabismus examination system. By using the shutter glasses that can control the cover state electrically, cover-uncover test and alternate-cover test are performed according to the flowchart. Test is started by capturing the infrared video images acquired by camcorder. And we can measure the deviation of the eye from the difference of the pupil center and the corneal reflex point. By following the flowchart, type of strabismus could be determined. Developed device showed good results comparable to conventional coveruncover test and alternate cover test.

AB - This paper is to discuss about how to implement the automatic strabismus examination system. By using the shutter glasses that can control the cover state electrically, cover-uncover test and alternate-cover test are performed according to the flowchart. Test is started by capturing the infrared video images acquired by camcorder. And we can measure the deviation of the eye from the difference of the pupil center and the corneal reflex point. By following the flowchart, type of strabismus could be determined. Developed device showed good results comparable to conventional coveruncover test and alternate cover test.

KW - Alternate-cover test

KW - Cover-uncover test

KW - Infrared image

KW - Shutter glasses

KW - Strabismus

UR - http://www.scopus.com/inward/record.url?scp=84937797436&partnerID=8YFLogxK

U2 - 10.1007/978-3-319-11128-5_36

DO - 10.1007/978-3-319-11128-5_36

M3 - Conference contribution

VL - 45

SP - 142

EP - 145

BT - 6th European Conference of the International Federation for Medical and Biological Engineering - MBEC 2014

A2 - Lackovic, Igor

A2 - Vasic, Darko

PB - Springer Verlag

ER -

Seo MW, Yang HK, Hwang J-M, Seo JM. The automated diagnosis of strabismus using an infrared camera. In Lackovic I, Vasic D, editors, 6th European Conference of the International Federation for Medical and Biological Engineering - MBEC 2014. Vol. 45. Springer Verlag. 2015. p. 142-145 https://doi.org/10.1007/978-3-319-11128-5_36