Performance evaluation of electrocardiogram measured using capacitive textiles on a bed

Hong Ji Lee, Seung Min Lee, Kang Moo Lee, Kwangsuk Park

Research output: Chapter in Book/Report/Conference proceedingConference contributionResearchpeer-review

3 Citations (Scopus)

Abstract

Devices for Ubiquitous-Healthcare have been currently developed to monitor health state unconsciously. Especially, measuring electrocardiogram (ECG) non-invasively on a bed has an advantage of long-term monitoring. We developed a simple and easy-to-use ECG measurement system on the bed with conductive textile sheets. It was arranged through experiments to monitor ECG more stable. Three male subjects participated in our experiment to measure ECG with four postures; a supine, prone, right lateral, and left lateral posture. Error rates of heart rate variability and correlation of RR-intervals were analyzed to evaluate the performance of the designed system. The results showed that the performance of the developed system was affected by environmental conditions, posture types and subjects.

Original languageEnglish
Title of host publicationBIODEVICES 2011 - Proceedings of the International Conference on Biomedical Electronics and Devices
Pages436-439
Number of pages4
StatePublished - 15 Jul 2011
EventInternational Conference on Biomedical Electronics and Devices, BIODEVICES 2011 - Rome, Italy
Duration: 26 Jan 201129 Jan 2011

Other

OtherInternational Conference on Biomedical Electronics and Devices, BIODEVICES 2011
CountryItaly
CityRome
Period26/01/1129/01/11

Fingerprint

Electrocardiography
Textiles
Experiments
Health
Monitoring

Keywords

  • Capacitive textile
  • Electrocardiogram (ECG)
  • Heart rate variability (HRV)

Cite this

Lee, H. J., Lee, S. M., Lee, K. M., & Park, K. (2011). Performance evaluation of electrocardiogram measured using capacitive textiles on a bed. In BIODEVICES 2011 - Proceedings of the International Conference on Biomedical Electronics and Devices (pp. 436-439)
Lee, Hong Ji ; Lee, Seung Min ; Lee, Kang Moo ; Park, Kwangsuk. / Performance evaluation of electrocardiogram measured using capacitive textiles on a bed. BIODEVICES 2011 - Proceedings of the International Conference on Biomedical Electronics and Devices. 2011. pp. 436-439
@inproceedings{f828c42295fa4f7b9aa0e1de2de9261e,
title = "Performance evaluation of electrocardiogram measured using capacitive textiles on a bed",
abstract = "Devices for Ubiquitous-Healthcare have been currently developed to monitor health state unconsciously. Especially, measuring electrocardiogram (ECG) non-invasively on a bed has an advantage of long-term monitoring. We developed a simple and easy-to-use ECG measurement system on the bed with conductive textile sheets. It was arranged through experiments to monitor ECG more stable. Three male subjects participated in our experiment to measure ECG with four postures; a supine, prone, right lateral, and left lateral posture. Error rates of heart rate variability and correlation of RR-intervals were analyzed to evaluate the performance of the designed system. The results showed that the performance of the developed system was affected by environmental conditions, posture types and subjects.",
keywords = "Capacitive textile, Electrocardiogram (ECG), Heart rate variability (HRV)",
author = "Lee, {Hong Ji} and Lee, {Seung Min} and Lee, {Kang Moo} and Kwangsuk Park",
year = "2011",
month = "7",
day = "15",
language = "English",
isbn = "9789898425379",
pages = "436--439",
booktitle = "BIODEVICES 2011 - Proceedings of the International Conference on Biomedical Electronics and Devices",

}

Lee, HJ, Lee, SM, Lee, KM & Park, K 2011, Performance evaluation of electrocardiogram measured using capacitive textiles on a bed. in BIODEVICES 2011 - Proceedings of the International Conference on Biomedical Electronics and Devices. pp. 436-439, International Conference on Biomedical Electronics and Devices, BIODEVICES 2011, Rome, Italy, 26/01/11.

Performance evaluation of electrocardiogram measured using capacitive textiles on a bed. / Lee, Hong Ji; Lee, Seung Min; Lee, Kang Moo; Park, Kwangsuk.

BIODEVICES 2011 - Proceedings of the International Conference on Biomedical Electronics and Devices. 2011. p. 436-439.

Research output: Chapter in Book/Report/Conference proceedingConference contributionResearchpeer-review

TY - GEN

T1 - Performance evaluation of electrocardiogram measured using capacitive textiles on a bed

AU - Lee, Hong Ji

AU - Lee, Seung Min

AU - Lee, Kang Moo

AU - Park, Kwangsuk

PY - 2011/7/15

Y1 - 2011/7/15

N2 - Devices for Ubiquitous-Healthcare have been currently developed to monitor health state unconsciously. Especially, measuring electrocardiogram (ECG) non-invasively on a bed has an advantage of long-term monitoring. We developed a simple and easy-to-use ECG measurement system on the bed with conductive textile sheets. It was arranged through experiments to monitor ECG more stable. Three male subjects participated in our experiment to measure ECG with four postures; a supine, prone, right lateral, and left lateral posture. Error rates of heart rate variability and correlation of RR-intervals were analyzed to evaluate the performance of the designed system. The results showed that the performance of the developed system was affected by environmental conditions, posture types and subjects.

AB - Devices for Ubiquitous-Healthcare have been currently developed to monitor health state unconsciously. Especially, measuring electrocardiogram (ECG) non-invasively on a bed has an advantage of long-term monitoring. We developed a simple and easy-to-use ECG measurement system on the bed with conductive textile sheets. It was arranged through experiments to monitor ECG more stable. Three male subjects participated in our experiment to measure ECG with four postures; a supine, prone, right lateral, and left lateral posture. Error rates of heart rate variability and correlation of RR-intervals were analyzed to evaluate the performance of the designed system. The results showed that the performance of the developed system was affected by environmental conditions, posture types and subjects.

KW - Capacitive textile

KW - Electrocardiogram (ECG)

KW - Heart rate variability (HRV)

UR - http://www.scopus.com/inward/record.url?scp=79960189248&partnerID=8YFLogxK

M3 - Conference contribution

SN - 9789898425379

SP - 436

EP - 439

BT - BIODEVICES 2011 - Proceedings of the International Conference on Biomedical Electronics and Devices

ER -

Lee HJ, Lee SM, Lee KM, Park K. Performance evaluation of electrocardiogram measured using capacitive textiles on a bed. In BIODEVICES 2011 - Proceedings of the International Conference on Biomedical Electronics and Devices. 2011. p. 436-439