Abstract
The personal protective equipment (PPE) used to minimize exposure to hazards can hinder healthcare workers from performing sophisticated procedures. We retrospectively reviewed 77,535 blood cultures (202,012 pairs) performed in 28,502 patients from January 2020 to April 2022. The contamination rate of all blood cultures was significantly elevated in the coronavirus disease 2019 ward at 4.68%, compared to intensive care units at 2.56%, emergency rooms at 1.13%, hematology wards at 1.08%, and general wards at 1.07% (All of P < 0.001). This finding implies that wearing PPE might interfere with adherence to the aseptic technique. Therefore, a new PPE policy is needed that considers the balance between protecting healthcare workers and medical practices.
Original language | English |
---|---|
Article number | e180 |
Journal | Journal of Korean Medical Science |
Volume | 38 |
Issue number | 23 |
DOIs | |
State | Published - 2023 |
Bibliographical note
Publisher Copyright:© 2023 The Korean Academy of Medical Sciences.
Keywords
- Blood Culture
- Coronavirus Disease 2019
- Personal Protective Equipment