Diagnostic Value of a Wearable Continuous Electrocardiogram Monitoring Device (AT-Patch) for New-Onset Atrial Fibrillation in High-Risk Patients: Prospective Cohort Study

Ju Seung Kwun, Jang Hoon Lee, Bo Eun Park, Jong Sung Park, Hyeon Jeong Kim, Sun Hwa Kim, Ki Hyun Jeon, Hyoung Won Cho, Si Hyuck Kang, Wonjae Lee, Tae Jin Youn, In Ho Chae, Chang Hwan Yoon

Research output: Contribution to journalArticlepeer-review

Abstract

Background: While conventional electrocardiogram monitoring devices are useful for detecting atrial fibrillation, they have considerable drawbacks, including a short monitoring duration and invasive device implantation. The use of patch-type devices circumvents these drawbacks and has shown comparable diagnostic capability for the early detection of atrial fibrillation. Objective: We aimed to determine whether a patch-type device (AT-Patch) applied to patients with a high risk of new-onset atrial fibrillation defined by the congestive heart failure, hypertension, age ≥75 years, diabetes mellitus, stroke, vascular disease, age 65-74 years, sex scale (CHA2DS2-VASc) score had increased detection rates. Methods: In this nonrandomized multicenter prospective cohort study, we enrolled 320 adults aged ≥19 years who had never experienced atrial fibrillation and whose CHA2DS2-VASc score was ≥2. The AT-Patch was attached to each individual for 11 days, and the data were analyzed for arrhythmic events by 2 independent cardiologists. Results: Atrial fibrillation was detected by the AT-Patch in 3.4% (11/320) of patients, as diagnosed by both cardiologists. Interestingly, when participants with or without atrial fibrillation were compared, a previous history of heart failure was significantly more common in the atrial fibrillation group (n=4/11, 36.4% vs n=16/309, 5.2%, respectively; P=.003). When a CHA2DS2-VASc score ≥4 was combined with previous heart failure, the detection rate was significantly increased to 24.4%. Comparison of the recorded electrocardiogram data revealed that supraventricular and ventricular ectopic rhythms were significantly more frequent in the new-onset atrial fibrillation group compared with nonatrial fibrillation group (3.4% vs 0.4%; P=.001 and 5.2% vs 1.2%; P<.001), respectively. Conclusions: This study detected a moderate number of new-onset atrial fibrillations in high-risk patients using the AT-Patch device. Further studies will aim to investigate the value of early detection of atrial fibrillation, particularly in patients with heart failure as a means of reducing adverse clinical outcomes of atrial fibrillation.

Original languageEnglish
Article numbere45760
JournalJournal of Medical Internet Research
Volume25
Issue number1
DOIs
StatePublished - Jan 2023

Bibliographical note

Publisher Copyright:
© 2023 Journal of Medical Internet Research. All rights reserved.

Keywords

  • AT-Patch
  • adult
  • arrhythmias
  • atrial fibrillation
  • electrocardiogram
  • heart failure
  • mobile phone
  • patch electrocardiogram monitor
  • wearable electronic device

Fingerprint

Dive into the research topics of 'Diagnostic Value of a Wearable Continuous Electrocardiogram Monitoring Device (AT-Patch) for New-Onset Atrial Fibrillation in High-Risk Patients: Prospective Cohort Study'. Together they form a unique fingerprint.

Cite this