TY - JOUR
T1 - Assessment of lymph node area coverage with total marrow irradiation and implementation of total marrow and lymphoid irradiation using automated deep learning-based segmentation
AU - Choi, Hyeon Seok
AU - Kang, Hyun Cheol
AU - Chie, Eui Kyu
AU - Shin, Kyung Hwan
AU - Chang, Ji Hyun
AU - Jang, Bum Sup
N1 - Publisher Copyright:
© 2024 Choi et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
PY - 2024/3
Y1 - 2024/3
N2 - Background Total marrow irradiation (TMI) and total marrow and lymphoid irradiation (TMLI) have the advantages. However, delineating target lesions according to TMI and TMLI plans is laborintensive and time-consuming. In addition, although the delineation of target lesions between TMI and TMLI differs, the clinical distinction is not clear, and the lymph node (LN) area coverage during TMI remains uncertain. Accordingly, this study calculates the LN area coverage according to the TMI plan. Further, a deep learning-based model for delineating LN areas is trained and evaluated. Methods Whole-body regional LN areas were manually contoured in patients treated according to a TMI plan. The dose coverage of the delineated LN areas in the TMI plan was estimated. To train the deep learning model for automatic segmentation, additional whole-body computed tomography data were obtained from other patients. The patients and data were divided into training/validation and test groups and models were developed using the "nnU-NET"framework. The trained models were evaluated using Dice similarity coefficient (DSC), precision, recall, and Hausdorff distance 95 (HD95). The time required to contour and trim predicted results manually using the deep learning model was measured and compared. Results The dose coverage for LN areas by TMI plan had V100% (the percentage of volume receiving 100% of the prescribed dose), V95%, and V90% median values of 46.0%, 62.1%, and 73.5%, respectively. The lowest V100% values were identified in the inguinal (14.7%), external iliac (21.8%), and para-aortic (42.8%) LNs. The median values of DSC, precision, recall, and HD95 of the trained model were 0.79, 0.83, 0.76, and 2.63, respectively. The time for manual contouring and simply modified predicted contouring were statistically significantly different. Conclusions The dose coverage in the inguinal, external iliac, and para-aortic LN areas was suboptimal when treatment is administered according to the TMI plan. This research demonstrates that the automatic delineation of LN areas using deep learning can facilitate the implementation of TMLI.
AB - Background Total marrow irradiation (TMI) and total marrow and lymphoid irradiation (TMLI) have the advantages. However, delineating target lesions according to TMI and TMLI plans is laborintensive and time-consuming. In addition, although the delineation of target lesions between TMI and TMLI differs, the clinical distinction is not clear, and the lymph node (LN) area coverage during TMI remains uncertain. Accordingly, this study calculates the LN area coverage according to the TMI plan. Further, a deep learning-based model for delineating LN areas is trained and evaluated. Methods Whole-body regional LN areas were manually contoured in patients treated according to a TMI plan. The dose coverage of the delineated LN areas in the TMI plan was estimated. To train the deep learning model for automatic segmentation, additional whole-body computed tomography data were obtained from other patients. The patients and data were divided into training/validation and test groups and models were developed using the "nnU-NET"framework. The trained models were evaluated using Dice similarity coefficient (DSC), precision, recall, and Hausdorff distance 95 (HD95). The time required to contour and trim predicted results manually using the deep learning model was measured and compared. Results The dose coverage for LN areas by TMI plan had V100% (the percentage of volume receiving 100% of the prescribed dose), V95%, and V90% median values of 46.0%, 62.1%, and 73.5%, respectively. The lowest V100% values were identified in the inguinal (14.7%), external iliac (21.8%), and para-aortic (42.8%) LNs. The median values of DSC, precision, recall, and HD95 of the trained model were 0.79, 0.83, 0.76, and 2.63, respectively. The time for manual contouring and simply modified predicted contouring were statistically significantly different. Conclusions The dose coverage in the inguinal, external iliac, and para-aortic LN areas was suboptimal when treatment is administered according to the TMI plan. This research demonstrates that the automatic delineation of LN areas using deep learning can facilitate the implementation of TMLI.
UR - http://www.scopus.com/inward/record.url?scp=85187499013&partnerID=8YFLogxK
U2 - 10.1371/journal.pone.0299448
DO - 10.1371/journal.pone.0299448
M3 - Article
C2 - 38457432
AN - SCOPUS:85187499013
SN - 1932-6203
VL - 19
JO - PLoS ONE
JF - PLoS ONE
IS - 3 March
M1 - e0299448
ER -